2/2 valve
| |
A directional control valve with two ways, two ports, and two positions.
|
|
3/2 valve
| |
A directional control valve with three ways, three ports, and two positions.
|
|
4/2 valve
| |
A directional control valve with four ways, four ports, and two positions.
|
|
4/3 valve
| |
A directional control valve with four ways, four ports, and three positions.
|
|
5/2 valve
| |
A directional control valve with four ways, five ports, and two positions.
|
|
5/3 valve
| |
A directional control valve with four ways, five ports, and three positions.
|
|
accumulator
| |
A hydraulic component used to store hydraulic fluid. Accumulators are designed to increase or relieve pressure in the system.
|
|
advance
| |
The forward movement of the piston. With a single-acting cylinder, work is usually performed on the advance of the piston.
|
|
air receiver
| |
A component that stores compressed gas and helps stockpile a constant supply of pressurized gas.
|
|
American National Standards Institute
| |
A private, non-profit organization that administers and coordinates voluntary standards and systems. Print symbols are standardized by ANSI.
|
|
bidirectional
| |
Moving in two different directions.
|
|
block diagram
| |
The simplest type of fluid power blueprint that represents a circuit with lines and basic shapes like blocks. Block diagrams do not use standard fluid symbols.
|
|
blueprint
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A blueprint with instructions for fluid systems contains a series of print symbols.
|
|
CAD
| |
Computer-aided design. CAD software helps fluid engineers to efficiently design schematics for fluid systems.
|
|
check valve
| |
A control valve that allows fluid to flow in one direction. Check valves prevent backflow.
|
|
component list
| |
An area of a blueprint that lists every fluid component in the fluid circuit.
|
|
compressor
| |
A component that pressurizes ambient air and directs it into a pneumatic system.
|
|
conductor
| |
A component such as a pipe, tube, or hose that conveys fluid throughout a fluid system.
|
|
connector
| |
A symbol that represents a fitting in a fluid print. Connectors are indicated by a solid dot.
|
|
control device
| |
A fluid component that initiates an action within a system.
|
|
control logic
| |
The part of the architecture of a fluid circuit that controls what the circuit is capable of doing.
|
|
cooler
| |
A component that lowers the temperature of compressed air.
|
|
cross
| |
A pipe fitting that joins one pipe run to another that runs perpendicular and through the main run.
|
|
cushion
| |
A noise control device that is attached to the piston on the advance, retract, or both.
|
|
cutaway diagram
| |
A type of fluid power blueprint that shows the internal mechanisms of each fluid component in the circuit.
|
|
cylinder
| |
A type of linear actuator that uses a piston to produce motion in a straight line. A cylinder is also known as a piston actuator.
|
|
dead-weight accumulator
| |
A component used to store hydraulic fluid. The dead-weight accumulator increases and relieves pressure through the use of a weighted vertical piston.
|
|
diagram
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A diagram with instructions for fluid systems contains a series of print symbols.
|
|
diesel engine
| |
A type of internal combustion engine, controlled by a throttle, that is often used as a prime mover for mobile fluid power applications.
|
|
direction of flow in a hydraulic system
| |
A fluid symbol that indicates the direction of liquid flow. The direction of hydraulic flow is represented by a solid arrow in a blueprint.
|
|
direction of flow in a pneumatic system
| |
A fluid symbol that indicates the direction of air flow. The direction of pneumatic flow is represented by an unfilled arrow in a blueprint.
|
|
directional control valve
| |
A fluid component that helps move fluids in certain directions during operation.
|
|
double shutoff quick disconnect fitting
| |
A quick disconnect fitting with one valve located in the stud connected to the hose and another valve located inside the fitting component that attaches closest to the air supply.
|
|
double-acting cylinder
| |
A fluid power actuator that directs energy in two directions.
|
|
double-end rod
| |
A rod that extends from the piston on both sides.
|
|
drain line
| |
A line that leads to a drain in a hydraulic system. A drain line is represented by a broken line with several breaks.
|
|
drawing
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A drawing with instructions for fluid systems contains a series of symbols.
|
|
efficiency
| |
A measure of the work output of a system versus the total energy input. An efficient system is able to convert a greater amount of the supplied energy into the intended useful work.
|
|
electric motor
| |
A machine that converts electricity into mechanical energy or motion. An electric motor is a type of prime mover for a fluid system.
|
|
filter
| |
A screen used for trapping very fine and fine particulate matter.
|
|
fitting
| |
A fluid component that connects, redirects, extends, or terminates the run of a fluid conductor.
|
|
fixed displacement
| |
Having a fluid capacity that is not changeable.
|
|
fixed output
| |
The amount of fluid passing through a valve at a set and unchanging flow rate.
|
|
fixed restriction
| |
An orifice that meters flow and is not adjustable.
|
|
flexible line
| |
Any working line such as a hose that is designed to bend and flex. A flexible line is represented in a print by a U-shaped solid line.
|
|
flow
| |
The directional movement of fluid in a fluid system. Flow in a fluid system can be laminar or turbulent.
|
|
flow control valve
| |
A type of valve consisting of a needle valve and a check valve placed in close proximity in a common body. Flow control valves regulate the flow of hydraulic fluid.
|
|
fluid circuit
| |
The path that a fluid follows in a fluid system. Fluid circuits are designed using blueprints.
|
|
fluid symbol
| |
A standardized symbol that represents a fluid component in a graphic diagram.
|
|
gas-loaded accumulator
| |
A component used to store hydraulic fluid. The gas-loaded accumulator increases and relieves pressure through the use of an inflatable bag. Also called an air-operated accumulator.
|
|
gauge
| |
A device that measures fluid power variables such as temperature and pressure during operation.
|
|
graphic diagram
| |
A type of fluid power blueprint that represents each fluid component with a standard symbol.
|
|
heat engine
| |
A device that converts heat energy into mechanical or electrical energy. A heat engine is a type of prime mover.
|
|
hydraulic pump
| |
A mechanical device used to move liquids in a hydraulic system.
|
|
inlet
| |
The opening on the side of a pump through which fluid is drawn into the pump.
|
|
installation diagram
| |
A type of fluid power blueprint that shows the external appearance of each fluid component in the circuit. Installation diagrams are also called pictorial diagrams.
|
|
integrated component
| |
A component that is designed to eliminate unnecessary fittings and seals. Integrated components significantly reduce the chances of leakage and contamination.
|
|
intensifier
| |
Hydraulic components that convert the low pressure from a large linear actuator into high pressure in a small linear actuator. Intensifiers are usually two different-sized cylinders connected by a common piston.
|
|
International Organization for Standardization
| |
An organization based in Switzerland that develops and publishes standards for its international membership base. It is often referred to as ISO.
|
|
legend
| |
An area of a blueprint that lists notes and otherwise provides the meaning of the symbols or pictures in a fluid blueprint.
|
|
lever
| |
A fluid power control that activates or deactivates a valve or actuator. Levers are operated by hand and may have more than two positions.
|
|
line
| |
A component such as a pipe, tube, or hose that conveys fluid throughout a fluid system.
|
|
line to reservoir above fluid level
| |
A line leading to a reservoir that terminates above the fluid level.
|
|
line to reservoir below fluid level
| |
A line leading to a reservoir that terminates below the fluid level.
|
|
linear actuator
| |
An actuator that directs force in a straight line. A cylinder is a linear actuator.
|
|
lubricator
| |
A component that releases an oil mist into certain portions of a pneumatic system to lubricate moving parts.
|
|
manual control
| |
A control device that requires an operator to activate or deactivate.
|
|
mechanical energy
| |
Energy used to perform work through the physical interaction and motion of instruments or tools.
|
|
motor
| |
An actuator that directs force in a circular motion. Motors are sometimes called rotary actuators.
|
|
needle valve
| |
A valve that adjusts the flow of fluid between and including fully on and fully off. The needle valve consists of a sharp conical obstruction that is extended or retracted to block or allow flow.
|
|
non return check valve
| |
A control valve that allows fluid to flow in one direction. This check valve does not allow the fluid to flow backwards in the circuit.
|
|
normally closed
| |
A fluid component such as a valve that is in the closed position when not activated.
|
|
normally open
| |
A fluid component such as a valve that is in the open position when not activated.
|
|
outlet
| |
The opening on the side of a pump through which fluid is expelled into the hydraulic system.
|
|
passing line
| |
A line that is not connected to another at the point at which they cross. To indicate that the two lines are not connected, one line has a U-shape at the crossing point.
|
|
pedal
| |
A fluid power control that activates or deactivates a valve or actuator. Pedals are usually located on the floor and are operated by foot.
|
|
pictorial diagram
| |
A type of fluid power blueprint that shows the external appearance of each fluid component in the circuit. Pictorial diagrams are also called installation diagrams.
|
|
pilot line
| |
A passage that transmits fluid pressure to control another device. Pilot lines are represented in a fluid symbol by a broken line.
|
|
plotter
| |
A large printer used to print fluid schematics. These output devices support vector graphics, unlike dot-matrix and laser printers.
|
|
plug
| |
A pipe fitting that terminates a run by closing an end. A plug has OD threads and is represented in a print by an X.
|
|
port
| |
An opening on a valve through which fluid can flow.
|
|
position
| |
The number of physical settings on a directional control valve. A three-position valve can be placed in three different physical settings with a control such as a lever.
|
|
press
| |
A machine with a stationary base and an upper ram that moves along a vertical axis to shear, bend, or form sheet metal.
|
|
pressure compensated
| |
Capable of providing an adjustable flow rate independent of the changes in inlet or outlet pressure.
|
|
pressure control valve
| |
An adjustable control valve that regulates pressure in a fluid system.
|
|
pressurized reservoir
| |
The main holding tank for hydraulic fluid that is closed to external environmental conditions. A pressurized reservoir is represented in a print by a closed rectangle.
|
|
prime mover
| |
The component of a hydraulic or pneumatic system that powers the main pump or compressor.
|
|
print
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A print with instructions for fluid systems contains a series of print symbols.
|
|
push button
| |
A fluid power control that activates or deactivates a valve or actuator. Push buttons are operated by hand and usually have two positions.
|
|
quick disconnect fitting
| |
A fitting designed for use with components that are moved often and without disrupting system air pressure or compromising safety.
|
|
reducing valve
| |
An adjustable control valve that regulates pressure in a particular zone of a fluid power system.
|
|
regulating valve
| |
A component that monitors gas passageways in a pneumatic system in order to maintain a consistent pressure level.
|
|
relief valve
| |
A non-adjustable control valve that regulates pressure in a fluid system. When a critical pressure is exceeded, the relief valve releases.
|
|
reservoir
| |
The main holding tank for hydraulic fluid.
|
|
retract
| |
The backward movement of the piston. The piston retracts so that it is position to advance.
|
|
rotary actuator
| |
An actuator that directs force in a circular motion. Rotary actuators are sometimes called motors.
|
|
schematic
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A schematic with instructions for fluid systems contains a series of print symbols.
|
|
separator
| |
A component that removes water from cooled air so that it does not build up and damage the pneumatic system.
|
|
sequence valve
| |
A control valve that allows hydraulic fluid to flow into another area of the system once a critical pressure has been achieved.
|
|
shut-off valve
| |
A valve that controls the on-and-off supply of fluid to or within a fluid system. A shut-off valve is represented in a blueprint with two facing arrows.
|
|
shuttle valve
| |
A control valve that regulates the supply of fluid from more than one source into a single area of the circuit.
|
|
single-acting cylinder
| |
A fluid power actuator that directs energy in one direction.
|
|
single-end rod
| |
A rod that extends from the piston on one side.
|
|
sketch
| |
A document containing all the instructions necessary for building and maintaining a fluid circuit. A sketch with instructions for fluid systems contains a series of print symbols.
|
|
spring-loaded accumulator
| |
A component used to store hydraulic fluid. The spring-loaded accumulator increases and relieves pressure through the use of a spring-loaded piston.
|
|
spring-loaded check valve
| |
A control valve that allows fluid to flow in one direction. The resistance of the valve is controlled by a spring.
|
|
steam engine
| |
A type of engine that is powered by steam and is used for very large fluid power applications.
|
|
straight through quick disconnect fitting
| |
A quick disconnect fitting with no valves. Straight through quick disconnect fittings cannot be added or removed without first shutting off the air supply.
|
|
strainer
| |
A screen used for trapping large and coarse particulate matter.
|
|
tee
| |
A pipe fitting that joins one pipe run to another that runs in one direction perpendicular to the main run.
|
|
temperature compensated
| |
Capable of providing an adjustable flow rate independent of the changes in temperature and oil viscosity.
|
|
throttle
| |
A control used to vary the speed of a mechanical device such as an engine.
|
|
throttle valve
| |
A control valve that regulates the variable amount of fluid that is supplied to another fluid component such as an actuator
|
|
unidirectional
| |
Moving in only one direction.
|
|
variable displacement
| |
Having a fluid capacity that is changeable. Variable displacement is indicated in a fluid symbol by a slanted arrow.
|
|
variable output
| |
The amount of fluid passing through a valve at a non-uniform and changeable flow rate.
|
|
vented reservoir
| |
The main holding tank for hydraulic fluid that is open to external environmental conditions. A vented reservoir is represented in a print by a three-sided rectangle.
|
|
way
| |
A characteristic of a valve that indicates how a fluid can flow through the valve. To determine the number of ways on a valve, take the number of arrows in one position and multiply by two. 3-way valves get their name from the number of ports in one position.
|
|
working line
| |
Any active line in a fluid system. A working line is represented in a print by a solid line.
|
|
wye
| |
A pipe fitting that joins one pipe run to another that runs in one direction at 45° to the main run.
|